System-on-Chip Solution for Ultrasonic Flow Metering
The TDC-GP30 is the next generation in ams (previously acam) development for Ultrasonic Flow Converters. It drastically simplifies the design of ultrasonic heat and water meters and is the necessary step for compact energy-saving ultrasonic water meters. The ultra-low-current capabilities allow the use of standard 2/3 AA or AA lithium batteries at 6-8Hz measuring frequency as needed for water meter. The GP30 is a system-on-chip that allows you to perform all measurement tasks in one IC.
Analog Frontend | Yes |
First Wave Detection | Yes |
Amplitude Measurement | Yes |
Number of Hits | 31 |
Resolution [ps] | 11 |
Operating Supply Range | 2.5 to 3.6 |
Interface | SPI, UART, Pulse |
CPU | 32-bit |
Memory | 4k NVRAM, 4k ROM |
GPIO | 6 |
Ambient Temperature Range [°C] | -40°C to +125°C |
Package | QFN32, QFN40 |
Description | Version | Size | Download |
---|---|---|---|
Datasheet AS6040 Vol. 1: Ultrasonic Flow Meter for Gas & Water Meters | V0.1 | 1.2MB | AS6040-sc-000854-ds-2-1.pdf |
Datasheet TDC-GP30 Vol. 1: System-Integrated Solution for Ultrasonic Flow Meters General Data and Frontend Description | V0.1 | 1.2MB | DB_GP30_Vol1.pdf |
Datasheet TDC-GP30 Vol. 2: System-Integrated Solution for Ultrasonic Flow Meters CPU, Memory and Firmware | V0.0 | 1.3MB | DB_GP30_Vol2.pdf |
Datasheet TDC-GP30 Vol. 3: System-Integrated Solution for Ultrasonic Flow Meters: User Manual | V0.0 | 1.3MB | DB_GP30_Vol3.pdf |
Datasheet TDC-GP30 Vol. 4: Firmware, Memory and ROM Overview: User Manual | V0.5 | 2MB | DB_GP30_Vol4_en.pdf |
Datasheet TDC-GP22 Eval System: Evaluation System for TDC-GP22 | V0.2 | 5.3MB | DB_GP22-EVA_en.pdf |
Datasheet TDC-GP22: Universal 2-Channel TDC-GP22 dedicated to Ultrasonic Heat & Water Meters | V0.9 | 4MB | DB_GP22_en.pdf |
Datasheet TDC-GP21 Eval System: Evaluation System for TDC-GP21 | V0.0 | 5.3MB | DB_GP21-EVA_en.pdf |
Datasheet TDC-GP21: Universal 2-Channel TDC-GP21 | V1.6 | 4MB | DB_GP21_en.pdf |
Development Support TDC-GP30: Eval Kit Manual for TDC-GP30 | V1.0 | 2.5MB | GP30Y-EVA-KIT.pdf |
Development Support TDC-GP30: Demo Kit Manual for TDC-GP30 | V1.0 | 3MB | GP30-DEV-KIT.pdf |
Development Support TDC-GP22: Evaluation System for TDC-GP22 DEMO KIT | V0.0 | 2.4MB | DB_GP22-DEMO_en.pdf |
Development Support TDC-GP22: Evaluation System for TDC-GP22 | V0.2 | 2.8MB | DB_GP22-EVA_en.pdf |
Development Support TDC-GP21: Evaluation System for TDC-GP21 | V0.0 | 5.3MB | DB_GP21-EVA_en.pdf |
Description | Version | Size | Download |
---|---|---|---|
Application Note: TDC-GP30 External circuit for gas meters | V1.01 | 2MB | GP30 Application note Gas Meter.pdf |
Application Note: TDC-GP30-F01 Scaling calibration coefficients by 2-point calibration | V1.01 | 1.5MB | GP30-F01 Application note 2pt Calibration.pdf |
Application Note 032: Ultrasonic Water & Heat Metering with the TDC-GP22 | V1.2 | 1.5MB | AN032_en.pdf |
Application Note 029: Ultrasonic Heat Metering with the TDC-GP21 | V1.1 | 3.6MB | AN029_en.pdf |
Description | Version | Size | Download |
---|---|---|---|
Software AS6040 Evaluation Software for UFC AS6040 | V1 | 2.94MB | UFCEvaluationSoftware v1.0.0.zip |
Software TDC-GP30 / TDC-GP30-F01 Software package for GP30 Demo Kit | V1.7.0 | 237MB | acam_GP30-DEMO-KIT.zip |
Software TDC-GP30-F01 Calibration Engine for GP30 | V5.0 | 169MB | acam_GP30y_Calibration_Installer.zip |
Software TDC-GP30-F01 Open part of the acam Firmware A1.A2.11.03 | A1.D2.x | 259KB | acam_FW_A1.A2.11.XX.zip |
Software TDC-GP30-F01 Open part of the acam Firmware A1.D2.11.04 | A1.D2.x | 35KB | acam_FW_A1.D2.11.04.zip |
TDC-GP30 EvalSW TDC-GP30 EvalSW Calibration Engine | v55 | 2.79MB | TDC-GP30_EvalSW_Calibration_Engine_v55.zip |
TDC-GP30 EvalSW TDC-GP30 EvalSW | v1-7-0 | 231.36MB | TDC-GP30_EvalSW_v1-7-0.zip |
Software TDC-GP22: Software package for GP22-EVA-KIT | V1.9 | 111MB | CD-GP22-EVA-XP-WIN7.zip |
Software TDC-GP22: STM32 µC Sample code | 34k | GP22_main_AN032.c | |
Software TDC-GP21: Software package for GP21-EVA-KIT | V3.9 | 104MB | CD-GP21-EVA-XP-WIN7.zip |
Software PICOPROG V3.0(V2.0): Driver Installer Stand Alone | R12 | 5MB | PicoProg_v2_Driver_Installer_Stand-Alone_r11.zip |
Description | Version | Size | Download |
---|---|---|---|
Video: TDC-GP30 Doc Configuration Video | V1 | 16.27MB | TDC-GP30 Doc Configuration Video |
Screencast TDC-GP30-F01: 2-Point Calibration with ams/acam Firmware Scaling calibration coefficients by 2-point calibration | 9MB | GP30_SUMTOF_Cal.zip |
Type | Part number | Package | RoHS compl. | Shipping package |
---|---|---|---|---|
TDC-GP22: | ||||
TDC-GP22 | MNR 1949 | QFN32 | Yes | Tray |
TDC-GP22 | MNR 1950 | QFN32 | Yes | Tape & Reel (5k) |
GP22-EVA-KIT | MNR 1951 | System | Yes | Box |
GP22-DEMO-KIT | MNR 1979 | System | Yes | Box |
TDC-GP21: | ||||
TDC-GP21 | MNR 1839 | QFN32 | Yes | Tray |
TDC-GP21 | MNR 1720 | QFN32 | Yes | Tape & Reel (3K/5K) |
GP21-EVA-KIT | MNR 1781 | System | Yes | Box |
TDC-GP2: | ||||
TDC-GP2 | MNR 1058 | QFN32 | Yes | Tray |
TDC-GP2 | MNR 1480 | QFN32 | Yes | Tape & Reel (2k) |
TDC-GP1: | ||||
TDC-GP1 | MNR 278 | TQFP44 | Yes | Tray |
TDC-GPX: | ||||
TDC-GPX | MNR 975 | TQFP100 | Yes | Tray |
TDC-GPX-FG | MNR 1089 | TFBGA120 | Yes | Tray |