Ultrasonic Flow Converters

TDC-GP30-F01 ULTRASONIC FLOW CONVERTER

Firmware Supported Intelligent Ultrasonic Flow Converter

The TDC-GP30-F01 includes flow calculation making the TDC-GP30-F01 a complete ultrasonic flow metering solution that dramatically simplifies the design of ultrasonic water and heat meters. This is a vital step for compact energy-saving ultrasonic water meters.

Due to the ultra-low current capabilities, standard 2/3 AA or AA lithium thionyl chloride batteries can be used at 6-8 Hz measuring frequency even in the water meter version. The TDC-GP30-F01 firmware accomplishes the linearization and temperature compensation based on spool piece precise calibration data and completes the system-on-chip approach.

TDC-GP30-F01 – Ultrasonic flow converters

Ultrasonic Flow Converters (UFC)

KEY FEATURES

  • High performance + ultra-low power 32-Bit CPU with 4k NVRAM and 4k ROM
  • Advanced high-precision analog part
  • Advanced high-precision analog part
  • Transducers can be connected directly to GP30, no external components required
  • Firmware for calculation of flow, volume and temperature, including linearization and two-point calibration
  • Firmware adopts automatically to zero flow (2 Hz) or flow (8 Hz) condition
  • Error handling, bubble detection

KEY BENEFITS

  • Lowest power solution for ultrasonic water meters
  • On-chip firmware allows fastest time-to-market
  • Best measurement performance for leakage detection

TDC-GP30-F01 PRODUCT FACTS

Analog Frontend Yes
First Wave Detection Yes
Amplitude Measurement Yes
Number of Hits 31
Resolution [ps] 11
Operating Supply Range 2.5 to 3.6
Interface SPI, UART, Pulse
CPU 32-bit
Firmware Volume & Flow & Temperature Calculation
Memory 4k NVRAM, 4k ROM
GPIO 6
Ambient Temperature Range [°C]    -40°C to +125°C
Package QFN32, QFN40

Documentation & Downloads

AS6040 Documentation & Downloads

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Datasheet

Description

Datasheet AS6040 Vol. 1:
Ultrasonic Flow Meter for Gas & Water Meters

Version

V0.1

Size

1.2MB

Download

AS6040-sc-000854-ds-2-1.pdf

Description

Datasheet TDC-GP30 Vol. 1:
System-Integrated Solution for Ultrasonic Flow Meters General Data and Frontend Description

Version

V1.0

Size

1.2MB

Download

DB_GP30_Vol1.pdf

Description

Datasheet TDC-GP30 Vol. 2:
System-Integrated Solution for Ultrasonic Flow Meters CPU, Memory and Firmware

Version

V0.0

Size

1.3MB

Download

DB_GP30_Vol2.pdf

Description

Datasheet TDC-GP30 Vol. 3:
System-Integrated Solution for Ultrasonic Flow Meters: User Manual

Version

V0.0

Size

1.3MB

Download

DB_GP30_Vol3.pdf

Description

Datasheet TDC-GP30 Vol. 4:
Firmware, Memory and ROM Overview: User Manual

Version

V0.5

Size

2MB

Download

DB_GP30_Vol4_en.pdf

Description

Datasheet TDC-GP22 Eval System:
Evaluation System for TDC-GP22

Version

V0.2

Size

5.3MB

Download

DB_GP22-EVA_en.pdf

Description

Datasheet TDC-GP22:
Universal 2-Channel TDC-GP22 dedicated to Ultrasonic Heat & Water Meters

Version

V0.9

Size

4MB

Download

DB_GP22_en.pdf

Description

Datasheet TDC-GP21 Eval System:
Evaluation System for TDC-GP21

Version

V0.0

Size

5.3MB

Download

DB_GP21-EVA_en.pdf

Description

Datasheet TDC-GP21:
Universal 2-Channel TDC-GP21

Version

V1.6

Size

4MB

Download

DB_GP21_en.pdf

Description

Development Support TDC-GP30:
Eval Kit Manual for TDC-GP30

Version

V1.0

Size

2.5MB

Download

GP30Y-EVA-KIT.pdf

Description

Development Support TDC-GP30:
Demo Kit Manual for TDC-GP30

Version

V1.0

Size

3MB

Download

GP30-DEV-KIT.pdf

Description

Development Support TDC-GP22:
Evaluation System for TDC-GP22 DEMO KIT

Version

V0.0

Size

2.4MB

Download

DB_GP22-DEMO_en.pdf

Description

Development Support TDC-GP22:
Evaluation System for TDC-GP22

Version

V0.2

Size

2.8MB

Download

DB_GP22-EVA_en.pdf

Description

Development Support TDC-GP21:
Evaluation System for TDC-GP21

Version

V0.0

Size

5.3MB

Download

DB_GP21-EVA_en.pdf

Ordering Numbers

Type Part number Package RoHS compl. Shipping package
TDC-GP22:
TDC-GP22 MNR 1949 QFN32 Yes Tray
TDC-GP22 MNR 1950 QFN32 Yes Tape & Reel (5k)
GP22-EVA-KIT MNR 1951 System Yes Box
GP22-DEMO-KIT MNR 1979 System Yes Box
TDC-GP21:
TDC-GP21 MNR 1839 QFN32 Yes Tray
TDC-GP21 MNR 1720 QFN32 Yes Tape & Reel (3K/5K)
GP21-EVA-KIT MNR 1781 System Yes Box
TDC-GP2:
TDC-GP2 MNR 1058 QFN32 Yes Tray
TDC-GP2 MNR 1480 QFN32 Yes Tape & Reel (2k)
TDC-GP1:
TDC-GP1 MNR 278 TQFP44 Yes Tray
TDC-GPX:
TDC-GPX MNR 975 TQFP100 Yes Tray
TDC-GPX-FG MNR 1089 TFBGA120 Yes Tray

Ordering Numbers

Type Part number Package RoHS compl. Shipping package
TDC-GP22:
TDC-GP22 MNR 1949 QFN32 Yes Tray
TDC-GP22 MNR 1950 QFN32 Yes Tape & Reel (5k)
GP22-EVA-KIT MNR 1951 System Yes Box
GP22-DEMO-KIT MNR 1979 System Yes Box
TDC-GP21:
TDC-GP21 MNR 1839 QFN32 Yes Tray
TDC-GP21 MNR 1720 QFN32 Yes Tape & Reel (3K/5K)
GP21-EVA-KIT MNR 1781 System Yes Box
TDC-GP2:
TDC-GP2 MNR 1058 QFN32 Yes Tray
TDC-GP2 MNR 1480 QFN32 Yes Tape & Reel (2k)
TDC-GP1:
TDC-GP1 MNR 278 TQFP44 Yes Tray
TDC-GPX:
TDC-GPX MNR 975 TQFP100 Yes Tray
TDC-GPX-FG MNR 1089 TFBGA120 Yes Tray