Delay Line Detectors

Delay Line Detector

Detection of Electrons, Ions & Photons With SUB-NS Time Resolution.

Small Delay Line Detector

Small Imaging Detectors with Time Resolution (3D Detector Systems)

DLD-3030, DLD-3636, DLD-4040 (customized up to DLD-4545)

Imaging DLD with delay line anode area up to 45 x 45 mm².

High count rates, small deadtimes, compact design.

Typical applications: Electron Spectroscopy, Time Resolved Photoemission Electron Microscopy (TOF-PEEM), Mass Spectrometry (TOF-SIMS, RIMS, MALDI), X-ray microscopy, X-ray holography, X-ray spectroscopy.

Large Imaging Delay Line Detector - DLD

Large Imaging Detectors with Time Resolution (3D Detector Systems)

DLD-6565, DLD-8080, DLD-120120

Imaging DLD with delay line anode area up to 120 x 120 mm². High count rates, large active detector areas, high lateral resolution, large pixel numbers (up to 10,000 x 10,000).

Typical applications: Medium Energy Ion Scattering (MEIS), Atom Probe Microscopy (APM), Field Ion Microscopy (FIM), X-ray microscopy, X-ray holography, X-ray spectroscopy.

Line Detector with Time Resolution

Line Detectors With Time Resolution (1D-2D Detector Systems)

DLD-43, DLD-64

Line detectors for 1D (multi channel) / 2D (multi channel + time) detection in electron spectroscopy as well as for X-ray, UV, and charged particle applications.

Typical applications: multi channel detection in electron energy analyzers, X-ray and UV-diffraction.

4 Quandrant Delay Line Detector

Multi-Hit 4-Quadrant DLD Systems

DLD-3030-4Q

4-quadrant delay line detector for parallel multi hit detection of electrons, ions, UV and X-ray with burst count rates of above 100 MCPS.

Typical applications: Particle detection with extremely high burst count rates in pulsed experiments, e.g. mass spectrometry (TOF-SIMS, RIMS, MALDI).

Standard Delay Line Detector

DLDs for Use with a Photoemission Electron Microscope (PEEM)

DLD-3636

Standard delay line detector for photoemission electron microscopes. Delay line anode area: 36x36 mm&sub2; - mounting flange: DN63CF.

Interchangeable DLD

Interchangeable DLD-4040-IC

DLD mounted on a linear drive for in-situ exchange between DLD and the imaging unit of the PEEM. Delay line anode area: 40x40 mm&sub2;- mounting flange: DN63CF or DN100CF.

Delay Line Detector - DLD-3636-XR

Time Resolving X-ray, EUV Detectors

DLD-3636-XR

DLD with polyimid window for the laterally and timeresolved detection of X-rays. Delay line anode area: 36x36 mm&sub2;.